Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1933 1
1952 1
1963 1
1966 1
1968 2
1972 1
1975 2
1976 2
1977 1
1978 4
1979 3
1980 6
1981 7
1982 3
1983 9
1984 7
1985 4
1986 14
1987 8
1988 7
1989 17
1990 19
1991 25
1992 23
1993 24
1994 19
1995 30
1996 30
1997 35
1998 39
1999 35
2000 41
2001 41
2002 31
2003 38
2004 36
2005 40
2006 38
2007 56
2008 57
2009 60
2010 59
2011 59
2012 76
2013 66
2014 78
2015 43
2016 63
2017 63
2018 67
2019 94
2020 95
2021 96
2022 86
2023 102
2024 37

Text availability

Article attribute

Article type

Publication date

Search Results

1,755 results

Results by year

Filters applied: . Clear all
Page 1
Fine wire frame foot plate positioning.
King A, Ball N, Heidari N, Hughes A. King A, et al. Ann R Coll Surg Engl. 2018 Apr;100(4):341-342. doi: 10.1308/rcsann.2017.0150. Epub 2017 Oct 19. Ann R Coll Surg Engl. 2018. PMID: 29046087 Free PMC article. No abstract available.
Comparative analysis of external locking plate and combined frame external fixator for open distal tibial fractures: a comprehensive assessment of clinical outcomes and financial implications.
Bangura ML, Luo H, Zeng T, Wang M, Lin S, Chunli L. Bangura ML, et al. BMC Musculoskelet Disord. 2023 Dec 11;24(1):962. doi: 10.1186/s12891-023-07097-z. BMC Musculoskelet Disord. 2023. PMID: 38082305 Free PMC article.
This retrospective single-centre study aimed to compare the stability, clinical outcomes, complications, and financial implications of two surgical interventions, namely the external locking plate and the combined frame external fixator, to manage open distal tibial …
This retrospective single-centre study aimed to compare the stability, clinical outcomes, complications, and financial implications of two s …
Plate-Assisted Bone Segment Transport Versus Precice Bone Transport Nail.
Gardner MP, Beason AM. Gardner MP, et al. J Orthop Trauma. 2021 Oct 1;35(Suppl 4):S19-S24. doi: 10.1097/BOT.0000000000002123. J Orthop Trauma. 2021. PMID: 34533482 Review.
Plate-assisted bone segment transport (PABST) using the Precice limb lengthening nail has been adapted for use in bone transport with the use of a plate in an effort to eliminate the need for external fixation and its associated complications. ...PABST
Plate-assisted bone segment transport (PABST) using the Precice limb lengthening nail has been adapted for use in bone
A Combination of Ilizarov Frame, Externalized Locking Plate and Tibia Bridging for an Adult with Large Tibial Defect and Severe Varus Deformity Due to Chronic Osteomyelitis in Childhood: A Case Report.
Hong P, Ding Y, Xu R, Rai S, Liu R, Li J. Hong P, et al. Medicina (Kaunas). 2023 Jan 29;59(2):262. doi: 10.3390/medicina59020262. Medicina (Kaunas). 2023. PMID: 36837464 Free PMC article.
Corrective surgery consisted of three stages: lengthening with Ilizarov frame, removal of Ilizarov frame and fixation with externalized locking plate, and removal of externalized locking plate. ...In all, a combination of Ilizarov frame, externa …
Corrective surgery consisted of three stages: lengthening with Ilizarov frame, removal of Ilizarov frame and fixation with ext …
Mechanical Characterisation of GFRP Frame and Beam-to-Column Joints Including Steel Plate Fastened Connections.
Ferrara G, Helson O, Michel L, Ferrier E. Ferrara G, et al. Materials (Basel). 2022 Nov 22;15(23):8282. doi: 10.3390/ma15238282. Materials (Basel). 2022. PMID: 36499780 Free PMC article.
In this context, the mechanical performance of a fibre-reinforced polymer (FRP) frame, chosen as a structural solution for the building assembly, was investigated. Specifically, the research study aims to experimentally define the moment-rotation behaviour of screw-connect …
In this context, the mechanical performance of a fibre-reinforced polymer (FRP) frame, chosen as a structural solution for the buildi …
An Experimental Study on the Shear Hysteresis and Energy Dissipation of the Steel Frame with a Trapezoidal-Corrugated Steel Plate.
Shon S, Yoo M, Lee S. Shon S, et al. Materials (Basel). 2017 Mar 6;10(3):261. doi: 10.3390/ma10030261. Materials (Basel). 2017. PMID: 28772624 Free PMC article.
The hysteresis behavior and the energy dissipation capacity of the steel frame were also compared according to the corrugated direction of the plate. For the test, one simple frame model without the wall and two frame models reinforced with the plat
The hysteresis behavior and the energy dissipation capacity of the steel frame were also compared according to the corrugated directi …
Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures.
Esenkaya İ, Ünay K. Esenkaya İ, et al. Acta Orthop Traumatol Turc. 2011;45(3):156-61. doi: 10.3944/AOTT.2011.2584. Acta Orthop Traumatol Turc. 2011. PMID: 21765228 Free article. Clinical Trial.
OBJECTIVES: The aim of this prospective study was to evaluate the results of anatomical frame plate osteosynthesis in patients with Ada and Miller Type 2 or 4 scapula fractures. METHODS: Eleven Ada and Miller Type 2 or 4 scapula fractures in nine patients were treat …
OBJECTIVES: The aim of this prospective study was to evaluate the results of anatomical frame plate osteosynthesis in patients …
Finite element analysis comparison of Type 42A2 fracture fixed with external titanium alloy locking plate and traditional external fixation frame.
Fang S, Zhang L, Yang Y, Wang Y, Guo J, Mi L. Fang S, et al. J Orthop Surg Res. 2023 Oct 31;18(1):815. doi: 10.1186/s13018-023-04307-1. J Orthop Surg Res. 2023. PMID: 37907959 Free PMC article.
In this study, the biomechanical properties of titanium alloy locking plates and fixation brackets for treating Type AO/OTA 42A2 fractures were compared by applying the finite element method, and the results provided data support for the clinical application of the externa …
In this study, the biomechanical properties of titanium alloy locking plates and fixation brackets for treating Type AO/OTA 42A2 frac …
Frame-shifted APOBEC3A encodes two alternative proapoptotic proteins that target the mitochondrial network.
Caval V, Suspène R, Khalfi P, Gaillard J, Caignard G, Vitour D, Roingeard P, Vartanian JP, Wain-Hobson S. Caval V, et al. J Biol Chem. 2021 Sep;297(3):101081. doi: 10.1016/j.jbc.2021.101081. Epub 2021 Aug 14. J Biol Chem. 2021. PMID: 34403699 Free PMC article.
To understand this difference, we investigated the expression of two novel alternative "A3Alt" proteins encoded in the +1-shifted reading frame of the APOBEC3A gene. A3Alt-L and its shorter isoform A3Alt-S appear to be transmembrane proteins targeted to the mitochon …
To understand this difference, we investigated the expression of two novel alternative "A3Alt" proteins encoded in the +1-shifted reading
Plate-assisted Lengthening of the Femur and Tibia in Pediatric Patients.
Georgiadis AG, Rossow JK, Laine JC, Iobst CA, Dahl MT. Georgiadis AG, et al. J Pediatr Orthop. 2017 Oct/Nov;37(7):473-478. doi: 10.1097/BPO.0000000000000645. J Pediatr Orthop. 2017. PMID: 26368858
BACKGROUND: Limb lengthening over a percutaneous plate can be used during pediatric distraction osteogenesis to decrease the time of external fixation. METHODS: A retrospective, consecutive 2-surgeon experience of pediatric femoral and tibial lengthenings with a plate
BACKGROUND: Limb lengthening over a percutaneous plate can be used during pediatric distraction osteogenesis to decrease the time of …
1,755 results